Ecogate Workstation Activity Sensors

Overview

Connected to the gates, these sensors detect when a machine requires ventilation and when it does not. The gate board conveys sensor status to the control unit, greenBOX, via Modbus communication. Based on signal status from all machines, the greenBOX operates the Automatic Blast Gates, directing airflow to active machines, maintaining minimum transport air velocity in the duct system, and adjusting fan speed through the Variable Frequency Drive. This approach ensures designed suction at active workstations, while keeping inactive workstation gates closed to conserve energy and maintaining the required transport velocities within the ducting.

Ecogate offers a variety of sensor options. Standard Sensors are the most prevalent, used for over 95% of machines, as they can be connected to a wide range of voltage inputs, and they are simple to install. For more advanced scenarios where Standard Sensors may not suffice, our Premium Sensors offer enhanced capabilities.